Permit: T99CM04854

Parcel: 111070240


Addresses:

3333 E GRANT RD

Inspection Status: Correction Required

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
03/06/2000 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. WASTE AND VENT SYSTEM OK 2. OVERHEAD WATER DISTRIBUTION OK 3. ALL CORRECTIONS HAVE BEEN MADE 4. OK TO DRYWALL
02/29/2000 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. MUST USE SPECIALTY COUPLINGS WHEN CONNECTING DISSIMULAR MATERIAL ABS TO C.I. @ VENT AND WASTE 2. THERE CAN ONLY BE 1-90 @ DIETY ARM FOR BREAK RM SINK. IF YOU USE A 2 DIRTY ARM THEN TRAP MUST BE 2 TRAP MUST BE THE SAME SIZE AS DRAIN SERVED. 3. GAS PRESSURE TEST OK 4. GAS SHUT OFF VALVES FOR UNITS ON ROOF OK
02/29/2000 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0000*