Inspection Status: Correction Required
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 03/06/2000 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. WASTE AND VENT SYSTEM OK 2. OVERHEAD WATER DISTRIBUTION OK 3. ALL CORRECTIONS HAVE BEEN MADE 4. OK TO DRYWALL |
| 02/29/2000 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. MUST USE SPECIALTY COUPLINGS WHEN CONNECTING DISSIMULAR MATERIAL ABS TO C.I. @ VENT AND WASTE 2. THERE CAN ONLY BE 1-90 @ DIETY ARM FOR BREAK RM SINK. IF YOU USE A 2 DIRTY ARM THEN TRAP MUST BE 2 TRAP MUST BE THE SAME SIZE AS DRAIN SERVED. 3. GAS PRESSURE TEST OK 4. GAS SHUT OFF VALVES FOR UNITS ON ROOF OK |
| 02/29/2000 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0000* |