Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/06/2000 | PLUMBING - ROUGH, SOIL | Approved | ||
| 07/27/2000 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000* 1. SOIL WATER TEST OK 2. FLOOR DRAINS, FLOOR SINKS AND TRAP PRIMERS OK 3. WRAPPING OF ALL WASTE LINES IN BEARINGS OK 4. OK FOR CONCRETE 5. NOTE: GREASE TRAP HAS NOT BEEN INSTALLED AT THIS TIME |
|
| 07/26/2000 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999* 1. FLAT VENT FOR FUTURE FLOOR SINK HAS LEAK 2. RE TEST SYSTEM 3. SECURE VENT RISERS IN BEARING WITH BE BAR TO KEEP FROM BACKPITCH |
|
| 07/20/2000 | PLUMBING - ROUGH, SOIL | Partial Approval | PARTIAL ONLY TEST ON TRUNK AND BRANCHES ONLY PLEASE INSTALL END OF RUN CO AT P13 AS PER PLAN. INSTALL 2" FUTURE STUB W/VENT AS PER PLAN. PLEASE CORRECT ALL REVENTS BACK PITCH AT THIS TIME MAKE CORRECTIONS WRAP ALL ABS IN CONCRET AND CALL AGAIN W/ TEST |