Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T99CM04817
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/14/2000 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000* CORRECTIONS MADE COORDINATED WITH ARCHITECT TO ACCOMOLDATE ADA IN TIGHT QUARTERS OK FOR C OF PENDING ANY OTHER INPECTIONS |
|
10/27/2000 | PLUMBING - FINAL | Not ready for Inspection | NOT READY | |
10/26/2000 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999* ADA REQUIRES 29" MIN CLEAR UNDER HC LAVTORY HC WATER CLOSET NEEDS 36" OVERALL WILL WAIVE OBSTRUCTION ON LAV SIDE IF LAV IS RAISED TO MEET ADA EXPANSION TANK REQURES SUPPORT RPPBP CERTIFICATION TO BE VERIFIED BY TUCSON WATER |