Permit: T99CM04756

Parcel: 12110001B


Addresses:

4725 E PIMA ST


Inspection Status: Correction Required

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T99CM04756

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Correction Required

Date Description Inspector Results Comments
02/24/2000 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. WASTE AND VENT SYSTEM OK 2. OVERHEAD WATER DISTRIBUTION OK 3. OK TO DRYWALL 4. ALL CORRECTIONS HAVE BEEN MADE
02/17/2000 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. ABS HORIZONTAL VENTS MUST HAVE A HANGER EVERY 4 2. URNIAL DRAIN CANNOT CONNECT TO C.O. TEE MUST BE A DRAINAGE FITTING BOTH URNIALS 3. OVERHEAD HORIZONTAL COPPPER MUST HAVE HANGERS EVERY 8 4. LOOSE COPPER WATER LINES BY WATER HTR
02/17/2000 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0000*