Permit: T99CM04721

Parcel: 108202490


Addresses:

1266 E WEIMER CI

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/28/2000 FRAMING Approved
02/16/2000 FRAMING Correction Required ADDTL COMMS - PARTIAL - NEED APPROVED TRUSS SUBMITTAL.
02/16/2000 FRAMING Partial Approval IVRS - Inspection 0000$
02/09/2000 FRAMING Correction Required ADDTL COMMS - 1. NEED APPROVED TRUSS SUBMITTAL. 2. NAIL CUPPLES OF GARAGE DOOR. 3. NAIL NAILS IN BEARING HANGERS. GUARDRAIL TO BE AT 42 IN HEIGHT. 4. SHEARING TO GO TO UNDERSIDE OF SHEETING. 5. NEED ENG REPAIR TO TRUSS THAT NEEDS REPAIRS. 6. REPAIR DRYWALL AT UPPER FIREWALL. 7. INSTALL DRYWALL NAILER AT NORTH END OF FIREWALL. 8. NEED HANDRAIL BLOCKING #35. 9. NEED BLOCKING AT 16O.C. OVER GARAGE DOOR OPENING. 10.NAIL SHEATING OFF 2 FOOTING.
02/09/2000 FRAMING Denied IVRS - Inspection 0000$
01/04/2000 FRAMING Correction Required ADDTL COMMS - AT UPPER FIRE/SHEAR WALL.
01/04/2000 FRAMING Partial Approval IVRS - Inspection 0000$