Inspection History Details
Inspection Status: Correction Required
Inspection History: MODULAR - ELECTRIC INSPECTION
Permit Number - T99CM04694
Inspection Description - MODULAR - ELECTRIC INSPECTION
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/23/1999 | MODULAR - ELECTRIC INSPECTION | Correction Required | ADDTL COMMS - 1.CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE NEUTRAL CONDUTOR AT GUTTER 2. INSTALL 1/2 K.O. SEAL AT ELECTRICAL PANEL | |
12/23/1999 | MODULAR - ELECTRIC INSPECTION | Denied | IVRS - Inspection 0999* | |
11/01/1999 | MODULAR - ELECTRIC INSPECTION | Correction Required | ADDTL COMMS - 1. PLANS AGAIN NOT ON SITE 2. USE CROUSE HINDS BREAKERS IN PANEL PER 110-3 3. SEAL UNUSED KNOCK OUT ON SIDE OR PANEL WITH K.O. SEAL (NOT ELECTRICAL TAPE) PER 110-12 4. GROUNDING LUG IN GUTTER IS LOOSE AND ENAMAL PAINT NEEDS TO BE REMOVE WHERE LUG IS CONNECTED (ALSO DONT DOUBLE LUG) 5. NEUTRAL MUST BE BONDED DO GROUNDING ELECTRODE CONDUCTOR PLEASE LEAVE THE PLANS AT ELEC SERVICE AT NEXT INSPECTION | |
11/01/1999 | MODULAR - ELECTRIC INSPECTION | Denied | IVRS - Inspection 0999* | |
10/22/1999 | MODULAR - ELECTRIC INSPECTION | Denied | DENIED |