Permit: T99CM04670

Parcel: 133090580

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Permit Number - T99CM04670

Inspection Description - PLUMBING - SEWER HCS CONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
09/25/2000 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection 0000*
P.O.C. OF NEW BLDG SEWER TO SEWER MAIN OK
OK TO BACKFILL TRENCH
09/23/2000 PLUMBING - SEWER HCS CONNECT Denied IVRS - Inspection 0999*
CAN NOT MAKE A HORIZONTAL TAP ON SEWER MAIN. VERTICAL OR 45 DEGREE ONLY
A DIRECTIONAL FITTING IS REQUIRED FOR A HORIZONTAL CONNECTION
MUST EXPOSE BLDG DRAIN TO BLDG SEWER CONNECTION
09/19/2000 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000*
1. SOIL WATER TEST OK
2. BLDG DRIAN IS STUBBED OUT OF BLDG WITH C.O. BLDG SEWER HAS NOT BEEN CONNECTED
3. SITE SEWER OK TO P.O.C. OF SEWER MAIN
4. MUST HAVE SURVEYOR TO CERTIFY VERIFICATION OF GRADE EVERY 50' PRIOR TO BACKFILL
5. OK TO BACKFILL TRENCH