Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/15/2000 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
11/20/2000 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection 0000*
11/13/2000 PLUMBING - GAS PRESSURE TEST Not ready for Inspection 1. PROVIDE #8 BARE COPPER GROUNDTO GAS. 2. FHA STRAP GAS AND BANG PLATE A/C HI-LOW. 3. PROVIDE 110V POWER TO GAS DRYER. 4. SECURE SHOWER DIVERTER. 5. COMPLETE ALL GROUNDS AT BOXES AND FIXTURES. 6. COMPLETE FIREPLACE INSTALLATION AND GAS TO FIREPLACE.