Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Partial Approval
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 08/12/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
RESULTS SHOULD HAVE BEEN CALLED IN BY INSPECTOR ON 08/09/04. 1) REINFORCED FOOTER AT EAST SIDE OK |
| 08/06/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Cancelled |
IVRS - AP canceled |
| 06/29/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
NO APPROVED PLANS ON SITE 9:35 AM |
| 03/18/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection 0000* |
| 03/02/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) DETAIL A PAGE 4/6 CALLS FOR 24" WIDE FOOTING MINIMUM 12" DEEP WITH 2-#4 REBAR HORIZONTAL AND #4 VERTICALS 2) REBAR MUST HAVE MINIMUM 4" CONCRETE ENCASEMENT 3) LAYOUT DOES NOT MATCH DETAIL 4) REINSPECTION FEE DUE |
| 02/26/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) COMPLY WITH DETAIL A PG 4/6 |
| 02/26/2001 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999* |