Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/18/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - NOT READY - USE H2.5 RAFTER CLIPS NOT A3.5 AT GARAGE WALL. 1. FROM LAST INSPECTION YOU NEED TO LEAVE THE FIREPLACE INSTALLATION BOOKLET ON SITE. I NEED TO READ IT. 2. YOU HAVE 0 PRESSURE ON GAS TEST. THE GAS LINE MUST BE CALCULATED FOR ITS DEMAND WHETHER IT IS ON ITS OWN PIPE SUPPLY TO METER OR NOT IF TYING INTO HOUSE GAS SYSTEM. ALL GAS APPLIANCES. 3. THEIR BTU RATING ARE NEEDED AS WELL AS ALL PIPE LENGTHS FROM METER TO EACH APPLIANCE. IS THE FIREPLACE A GAS LIGHTER WOOD BURNING OR JUST GAS? HOW ARE YOU GOING TO INSULATE BEHIND OR AT THE FRONT? 4. METAL ELECTRIC BOX NEEDS A BONDING SCREW. 5. WHAT IS YOUR HEAT SOURCE FOR THIS ROOM? FIREPLACE IS NOT AN APPROVED HEAT SOURCE. 6. WHAT ABOUT OLD CARPORT LIGHT? |
| 02/18/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 12/23/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000* |