Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T99CM04173

Parcel: 137294130


Addresses:

1851 W LIMERICK LN

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
02/22/2000 FRAMING Correction Required ADDTL COMMS - APPROVED - PROVIDE CALCULATIONS FOR CRUSHED AIR DUCT AT 2ND FLOOR.
02/14/2000 FRAMING Correction Required ADDTL COMMS - 1. PROVIDE REVISIONS REQUESTED BY INSPECTOR. 2. PROVIDE PROTECTION FOR ELECTRICAL, MECHANICAL PLUMBING ETC.... 3. PROVIDE POST TO BEAM CONNECTION UNDER STAIRWELL AT 21 GLU LAM GARAGE AND IN WATER HEATER AREA AT DOUBLE 2X2S. 4. PROVIDE PAPERWORK FOR CRUSHED RETURN AIR DUCT, 2ND FLOOR. 5. PROVIDE APPROVED BY CITY OF TUCSON TRUSS CALCULATIONS AND LAYOUT SHEET. 6. STRAP HEADER UNDER STAIRWELL.
02/14/2000 FRAMING Denied DENIED
02/10/2000 FRAMING Correction Required ADDTL COMMS - STOPPED INSPECTION - RE-FEED. 1. ALL SECOND STORY SHEAR WALLS ARE NOT NAILED PER SCHEDULE. 2. NO CROSS CONNECTIONS ARE ALLOWED AT WATER SOFTENER DISCHARGE. PROVIDE 1AIR GAP DISCHARGING INTO DTW. 3. ALL WINDOWS/DOOR HEADERS ARE NOT FRAMED PER DETAIL 3/SD3. 4. 2ND FLOOR RETURN AIR DUCT CRUSHED AT 90 DEGREE TURN TO OPENING. 5. MECHANICAL IS NOT BLOCKED ON 3 SIDES. 6. ELECTRIC NOT SECURED. OUT OF WALLS ON SECOND FLOOR. 7. NO POSITIVE CONNECTION MADE AT 5-1/2 X 21 GLB AT 4X8 POST IN GARAGE AT 3 CAR OPTION. 8. ELECTRIC AT ISLAND IS NOT APPROVED. INSTALLATION AS BUILT. PREVIOUS INSPECTOR ADVISED OF RE-FEE IF HOUSE WAS NOT READY. THIS HOUSE IS NOT READY FOR INTERMEDIATE INSPECTIONS. SUPERINTENDENT PLEASE WALK HOUSE WITH ALL TRADES BEFORE CALLING FOR RE-INSPECTION. SUBJECT TO RE-FEE AGAIN.
02/10/2000 FRAMING Denied IVRS - Inspection 0999*
02/08/2000 FRAMING Correction Required ADDTL COMMS - CANCELLED - CORRECT THE SAME ITEMS REQUESTED FOR PRIOR INSPECTIONS.
02/08/2000 FRAMING Denied CANCELLED
12/28/1999 FRAMING Correction Required ADDTL COMMS - ANCHOR BOLTS WITHIN 5/8 OF AN INCH FROM EDGE HAVE NOT BEEN REPLACED. THIS INSPECTION IS DENIED. NO APPROVED TRUSS CALCULATIONS AT REINSPECTION. FEE WILL BE ISSUED IF ITEMS REQUESTED ARE NOT COMPLIED WITH AT TIME OF NEXT INSPECTION.
12/28/1999 FRAMING Denied DENIED
12/21/1999 FRAMING Correction Required ADDTL COMMS - STOPPED INSPECTION. 1. ANCHOR BOLTS PROVIDE 12 FROM END AND 48 O.C. WHERE BOLTS ARE LESS THAN 5/8 FROM END, ADD BOLT ALSO ANY SINGLE PLATE NEEDS MIN 2 ABS. 2. PROTECT ELECTRICAL WITH BANG PLATES. 3. OVER NOTCHED DOUBLE TOP PLATE PROVIDE FHA STRAPS BOTH SIDES MIN 4 NAILS EACH SIDE. 4. PROTECT VACUMNLINES. 5. CLIP FLOOR TRUSSES. 6. NO TEST ON WATER LINES. 7. BLOCK MECHANICAL, 3 SIDES.
12/21/1999 FRAMING Denied DENIED