Permit: T99CM04145

Parcel: 12510006A


Addresses:

3689 E BROADWAY BL

Inspection Status: Approved

Inspection History: ELECTRIC - ABOVE CEILING

Date Description Inspector Results Comments
04/05/2001 ELECTRIC - ABOVE CEILING Approved IVRS - Inspection 0000*
03/21/2001 ELECTRIC - ABOVE CEILING Denied IVRS - Inspection 0245*
03/14/2001 ELECTRIC - ABOVE CEILING Denied IVRS - Inspection 0245* 1) INSTALL 2 EACH #8 SCREW THRU GRID T-BAR TO EACH FIXTURE, OFFSET ENDS.
2) DO NOT USE GRID SUPPORT WIRES TO SUPPORT MC CABELS
01/03/2001 ELECTRIC - ABOVE CEILING Not ready for Inspection IVRS - Inspection 0000*