Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/15/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - APPROVED - THANK YOU FOR THE REVISED TRUSS CALCULATIONS. PLEASE PROVIDE A CLEARER COPY. (REVISED 11-10-99 C.O.T.) ALSO, THE PLANS NEED TO BE REVISED TO SHOW A SINGLE B TRUSS AND REVISIONS APPROVED BY THE CITY OF TUCSON. WILL CHECK AT FUTURE HOUSE. PROCEED AT YOUR OWN RISK. |
| 10/28/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 10/26/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - (2ND INSPECTION RE-FEED.) 1. TRUSS DRAWINGS AND PLANS SHOW A DOUBLE B TRUSS, ONLY ONE TRUSS INSTALLED. 2. SHEAR TRANSFER AT GARAGE NOT NAILED. 3. SUPPORT VTR-ARM ABOVE SHEAR TRANSFER IN GARAGE. 4. PROVIDE 30 CLEAR IN FRONT OF FURNACE. 5. PROVIDE CROSS VENTALATION AT ATTIC V/A THE ROOF DROMER VENTS. STOPPED INSPECTION. |
| 10/26/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 10/21/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. MISSING P.A. AT REAR SHEAR. 2. STAPLES IN LAUNDRY/KIT VERTICAL DRAIN LINES AT B/PLATE. 3. BOTTOM PLATE AT LAUNDRY HALL WAY NOT NAILED (HEADER STUDS). 4. DAMPER MISSING FRONT BATH EXHAUST FAN. 5. REAR BATH H2o LINES TO TUB NOT CONNECTED TO SYS. 6. 1 CLR. FURN. FLUE TO COMBUSTIBLES. |
| 10/21/1999 |
FRAMING |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |