Inspection Status: Correction Required
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 09/01/1999 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. SOIL WATER TEST OK 2. WASTE AND VENT SYSTEM OK 3. WATER DISTRIBUTION OK 4. OK TO DRYWALL 5. ALL CORRECTIONS HAVE BEEN MADE |
| 08/31/1999 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - HOT AND COLD ARE REVERSED @ P-1 2. REMOVE OR PROVIDE ACCESS PANEL FOR 3/4 GATE VALVE IN WALL 3. PROVIDE LISTING ON NO HUB COUPLINGS SPECS CALL FOR M-G TYPE COUPLINGS |
| 08/31/1999 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0000* |