Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T99CM03945
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/19/2000 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
07/19/2000 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*1. SEAL WET AREAS, WATER, CLOSETS, VANITYS, CABINETS, ETC. 2. 2% GRADE GLOVE AWAY FROM BLDG. 3. FIRE CAULK CHINMEY GAS LINE PENETRATION OPEN OR REMOVE DAMPER. 4. COMPLETE PLUMBLING AT DAMPER. 5. CANNOT VARIFY WHERE CONDENSATION LINE TERMINATES. 6. SECURE DISHWASHER WASTE LINE TO WITHIN 2" OF FLOOD RING. 7. RETAINING WALL IS NOT ON PLAN PROVIDE PRIOR INSPECTION REQUEST AND PERMIT FOR WALL OCCUPANCY WILL NOT BE GRANTED UNTIL PERMIT IS SECURED. | |
07/12/2000 | BUILDING - FINAL | Denied | 1. HOSE BIBBS MISSING. 2. ADDRESS NOT POSTED. 3. 2% GRADE AWAY FROM HOUSE. 4. PROVIDE 12" CLEARANCE FROM SIDE OF DISCONNECT. 5. CAULK EXTERIOR PENETRATIONS OUTLETS ETC., PLUMBING NOT COMPLETE. 6. FLUE VENT HOT WATER SINGLE WALL 3 SCREWS MINIMUM AT JOINTS. 7. FIRE CAULK GAS AT CHIMNEY REMOVE OR CLAMP OPEN DAMPER. |