Inspection History Details
Inspection Status: Partial Approval
Inspection History: ELECTRIC - FINAL
Permit Number - T99CM03944
Inspection Description - ELECTRIC - FINAL
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/16/2001 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection 0000* | |
01/12/2001 | ELECTRIC - FINAL | Denied | 1. WATER HEATER AND MECHANICAL VENTS MISSING WEATHER CAPS. 2. A/C CONDENSER NOT INSTALLED. 3. ELECTRIC OUTLET ON W. WALL OF MASTER BEDROOM MISSING COVERED MUST INSTALL. NOTE: HOUSE, YOU MUST HAVE CAPABILITY TO COOL AT LEAST ONE ROOM TO AT TEMPERATURE OF 80% PRIOR TO OCCUPANCY. DO NOT OCCUPY. | |
01/08/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999*/1. 801 ADDRESS NUMBER IN MINIMUM 3" HIGH NUMERAL REQUIRED ON HOUSE. 2. CLEAN OUTS MUST BE TRIMMED TO GRADE AND THREADED CAPS INSTALLED. 3. GRADING NOT COMPLETE. 4. PLUMBING NOT COMPLETE. 5. BARE BULB LIGHT FIXTURES NOT ALLOWED IN CLOSETS. 6. ALL COUNTER ELECTRIC OUTLETS IN KITCHEN MUST BE GFCI PROTECTED. NOTE: WE CANNOT RELEASE GAS OR ELECTRIC UNTIL ALL WORK IS COMPLETE (INCLUDING GRADING) AND HOUSE IS READY TO OCCUPY. |