Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/26/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/08/2000 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*ABOVE CEILING OK TO INSULATE AND DRYWALL. DO NOT COVER LAUNDRY AND SHOWER VALVE AREA. /1. WATER NOT COMPLETE AT INCOMING RISER. 2. LAUNDRY TRAP MUST BE BETWEEN 6" + 18" OF FLLOR. 3. TUB AND SHOWER FIXTURES NOT IN SHOWERS MUST USE TEMP/PRESSURE BALANCED VALVE. 4. W/C FLOOR PLAN GAS MUST BE INSTALLED. 5. BOND GAS AND COPPER PLUMBING W/ #4 BOND WIRE CONNECTED IN VISIBLE LOCATION. |
| 05/23/2000 |
FRAMING |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |