Inspection Status: Denied
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/22/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 11/18/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - CORRECTIONS ARE INCOMPLETE. PROVIDE COMPARISON AND PROOF OF EQUAL VALUES ON NON-SIMPSON STAMPS. |
| 11/18/1999 |
FRAMING |
|
Denied |
DENIED |
| 11/17/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. FLOOR BRACING NOT PER NOTE 8 FRMG. PLAN. 2. AREA OVER GARAGE BEAM NOT PER 14 OF A 8. 3. AREA OVER LIV. RM.-JACK TRUSSES -NOT PER 6 OF A8. 4. BEARING WALLS MUST BE RED HEADED. AT STAIRWELL. 5. BEAM AND POSTS OVER KIT. PASS THRU. NOT CORRECTLY BUILT. 6. INCORRECT POST CAPS USED. ARCHITECT SPECIFIES SIMPSON. DO NOT INSULATE. |
| 11/17/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 11/16/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0950* |