Permit: T99CM03863

Parcel: 130121910


Addresses:

3755 E 32ND ST

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
03/29/2000 FRAMING Correction Required ADDTL COMMS - PARTIAL - MUST SEE REVISED PLAN FOR INSTALLING UNDERSIZE WINDOW IN BEDROOM.
03/29/2000 FRAMING Partial Approval IVRS - Inspection 0000*
03/01/2000 FRAMING Correction Required ADDTL COMMS - DENIED - NEXT FAILURE WILL REFEE. 1. CARPORT COLUMN IS NOT INSTALLED. REQUIRES 3-EACH #4 REBAR EACH WAY 3 FROM SOIL. 2. SEAL FLOOR PENETRATIONS. MUST INSPECT PRIOR TO DRYWALL. 3. PLAN MUST BE REVISED FOR INSTALLING AN UNDERSIZED BEDROOM WINDOW WITH INADEQUATE NATURAL LIGHT AND LESS THAN MINIMUM 5.7 SQ. FT.- 20 WIDE EGRESS AND ADDING SKYLIGHT.
03/01/2000 FRAMING Denied IVRS - Inspection 0999*
01/21/2000 FRAMING Denied IVRS - Inspection 0999*
01/19/2000 FRAMING Denied IVRS - Inspection 0999*
01/12/2000 FRAMING Correction Required ADDTL COMMS - 1. ACCESS PANEL REQUIRED TO TUB SLIP FITTING. 2. FIRE PLACE NO IN. 3. 2 INCH LAUNDRY DRAIN CAN NOT DRAIN INTO 1 1/2 EXISTING DRAIN. 4. ONE WINDOW IN N.W BEDROOM BLOCKED-INADIQUATE NATURAL LIGHT OR EGRESS. 5. 1/2 EXPANSION ANCHOR BOLTS REQURED PER PLAN-NOT 3/8.
01/12/2000 FRAMING Denied IVRS - Inspection 0950*