Permit: T99CM03825

Parcel: 141183830

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/27/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - SHEAR TRANSFER TO TRUSS AT ENTRY WALL?
09/23/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. O.S.B. ROOF SHEATHING NAILED IN EXCESS OF 6O.C. AT EDGES. 2. ROOF SHEATHING CANNOT BE NAILED WITHIN 3/8 OF EDGES. 3. ROOF SHEATHING NOT NAILED AT BACK EDGE OVER ENTRY. 4. BACKING REQUIRED FOR STUCCO/ROOF FLASHING AT VERTICAL SURFACE OF GABLE TRUSS OVER ENTRY. 5. COLUMN POST/TRUSS NOT CLIPPED AT ENTRY. 6. NAIL PROTECT PLUMBING AT PLATE CUTS. 7. DOUBLE 2X10 HEADERS REQUIRED AT 2 WINDOWS. 2X8 INSTALLED. 8. DRYWALL SHEAR WALLS WITH INTERSECTING INTERIOR WALLS REQUIRE CHANGES NAILED PER U.B.C. PROVIDE ENGINEERS DETAIL. 9. #7 SHEAR WALL LOOSE. NAIL ALL SHINERS. 10.PORCH H 2.5 CLIPS NOT NAILED. 11.HOLD DOWN MISSING AT FRONT OF HOUSE. PROVIDE ENGINEERS APPROVED REPAIR AND CITY OF TUCSON. 12.8/AP NOT COMPLIED WITH. STOPPED INSPECTION.
09/23/1999 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*