Permit: T99CM03786

Parcel: 141200350

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
11/19/1999 FRAMING Correction Required ADDTL COMMS - 1. FRAMING IS APPROVED SUBJECT TO BUILDER FURNISHING CLARIFICATIONS OF FRAMING DETAIL 14 PAGE A8. 2. BUILDER WILL ALSO FURNISH AN APPROVAL OF THE POST CAPS USED IN LIEU OF THE ENGINEERS SPECIFIED PRODUCT. SIMPSON ECC 66/PC US?
11/17/1999 FRAMING Correction Required ADDTL COMMS - SEE NOTES: CORRECTIONS REQD. 1. WTR. TEST OF 2ND FLOOR DWV-FLOOD TUBS. 2. WTR. PRESSURE TEST ALL SUPPLY LINES. 3. TERMINATE ELECTRICAL CABLE INTO EXHAUST FAN AT MSTR-BATH. 4. CLOTHES DRYER VENT TUBE OVER WTR. HTR.-NEEDS CEILING? 5. SEE DETAIL 14 OF A8-1/2 OSB WILL HAVE TO BE APPLIED (ABOVE GARAGE) TO WALL BETWEEN LEDGERS. 6. IT APPEARS THE PLANS DESIGNER WANTS THE JACK TRUSSES TO BE TRIMMED TO ALLOW THE END VERTICLE SUPPORTS TO ABUTT THE LEDGERS. HE SPECIFIED LU 210 HANGERS (2W X 10 HIGH) FOR THIS APPLICATION. 7. THE WRONG POST CAP HAS BEEN INSTALLED ON GARAGE 6X6 CENTER POST. 8. THE WRONG POST BASE HAS BEEN . 9. ADD 2X6 TRUSS BRACE FROM DBL. FLOOR TRUSSES TO WALL. USE A 2X6 BLOCK AT WALL TO NAIL BRACE BLOCK. SEE FRAMING NOTE 8
11/17/1999 FRAMING Denied IVRS - Inspection 0999*