Permit: T99CM03773

Parcel: 11806118E


Addresses:

1850 W KING AV


Inspection Status: Correction Required

Inspection History: BUILDING - FINAL

Permit Number - T99CM03773

Inspection Description - BUILDING - FINAL

Inspection Status - Correction Required

Date Description Inspector Results Comments
12/22/1999 BUILDING - FINAL Correction Required ADDTL COMMS - NO GAS.
10/15/1999 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*
10/08/1999 BUILDING - FINAL Correction Required ADDTL COMMS - 1. PAINT ALL ABS ON ROOF AND PVC. 2. A/C DISCONNECT PROVIDE BRACING AND INTERNAL COVER AND 35 AMP FUSES. 3. THERMOSTAT PENETRATION NEEDS CONDUIT COMING OUT OF ROOF JACK THEN CONNECTED TO FLEX CONNECTOR. 4. CONDENSOR FAN WIRING IS EXPOSED OUTSIDE BOX AND NEEDS TO BE CHECKED. 5. NAIL ALL ST22 STRAPS AT POST BEAM CONNECTIONS. 6. PROVIDE SERVICE RECEPT. WITHIN 250 OF A/C UNIT. 7. A/C UNIT DOES NOT WORK. - STOPPED INSPECTION.
10/08/1999 BUILDING - FINAL Denied DENIED