Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T99CM03751
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/28/1999 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - ENTRY REQUIRES HIP HANGER CHECK AT INTERMEDIATE OK TO DRY IN | |
09/28/1999 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | PARTIAL APPROVAL | |
09/24/1999 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. CABLE END TRUSSS MUST BE CLIPPED TO WALLS AT 32 O.C. 2. RSP4 STUD CLIPS NOT NAILED. FILL ALL HOLES. 3. NO TRUSS DRAWINGS ON SITE. 4. RSP4 CLIPS MUST BE NAILED THROUGH MANUFACTURED HOLES NOT DAMAGED BY AIR NAILER. REPLACE ALL DAMAGED RSP4 CLIPS. 5. NON OVERLAPPING DOUBLE TOP PLATES AT CORNERS. REQUIRE STRAPPING PER UBC. STOPPED INSPECTION. HOUSE NOT READY FOR INSPECTION. SUGGEST FRAME, SUPERINTENDENT ENSURE HOUSE IS READY PRIOR TO CALLING FOR INSPECTION. ANY NOT READY HOUSE IN THE FUTURE, MAY BE CHARED A REFEE. | |
09/24/1999 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999* |