Inspection Status: Denied
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T99CM03703
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Denied
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/04/2000 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0999* | |
| 12/10/1999 | ELECTRIC - INTERMEDIATE | Correction Required | ADDTL COMMS - 1. ALL ELECTRIC BOXES MUST BE MADE UP. 2. SECURE WIRES WITHIN 8 OF ELECTRIC BOXES 3. GROUND ALL METAL ELECTRIC BOXES 4. ELECTRIC OUTLETS ON EXISTING WALL NOT INSTALLED 5. NAIL PROTECT ALL WIRES WITHIN 1 1/4 OF WALL SURFACE 6. BATH GFCI MUST BE ON DEDICATED CIRCUIT 7. COPPER PLUMBING BELOW CEILING BY DOOR 8. UNDERSIZE 4 X 6 BEAM SPANNING 10 5 INDICATED ON PLAN AS EXISTING IS IN FACT NEW 9. EXTERIOR BEARING WALL MUST BE FRAMED WITH STUDS SPACED AT 16 O.C. - PRESENTLY 24 O.C. 10. ADDITION NOT FRAMED PER APPROVED PLAN. BUILD TOPLAN OR REVISE PLAN TO AS BUILT. PLAN MUST BE REACCOMPLISHED TO INDICATE ALL BEAM AND FRAMING MEMBER SIZES. 11. EXPOSE ALL ANCHORS | |
| 12/10/1999 | ELECTRIC - INTERMEDIATE | Denied | DENIED | |
| 11/01/1999 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0335* |