Inspection History Details
Inspection Status: Denied
Inspection History: FRAMING
Permit Number - T99CM03703
Inspection Description - FRAMING
Inspection Status - Denied
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/10/1999 | FRAMING | Denied | DENIED | |
| 11/29/1999 | FRAMING | Correction Required | ADDTL COMMS - 1. 2X6 RAFTERS APPEAR TO BE OVER NOTCHED ACROSS PATIO. 2. NO CLIPS HAVE BEEN INSTALLED TO DATE. 3. CAN NOT VARIFY BOLTS AT SOLE PLATE BECAUSE WALLS HAVE BEEN COVERED INSIDE AND OUT. 4. PROVIDE ONLY APPROVED PLANS WITH REVISIONS, AND PREVIOUS INSPECTIONS, AND PERMIT SIGN OR CARD. 5. ALL OTHER INTERMEDIATES NEED TO BE APPROVED BEFORE FRAMING CAN BE APPORVED. | |
| 11/29/1999 | FRAMING | Denied | DENIED | |
| 11/01/1999 | FRAMING | Correction Required | ADDTL COMMS - THE ROOMS HAVE NOT HAD FRAMING, PLUMBING AND OTHER ROUGH INSPECTIONS, BUT ARE DRYWALLED OVER. PLUMBING NOT YET IN GROUND 2X4 RAFTERS SPAN 12 (2X4S AT 24 O.C.) THE PLAN REQUIRES 2X6S FOR RAFTERS ELECTRICAL COVERED NO INSPECTION FRAMING APPEARS SUB-STANDARD THE PLAN AND THE ACTUAL WORK ARE DIFFERENT I ASKED THE HOMEOWNER TO RETURN TO DSC PLAN REVIEW AND EXPLAIN TO PERMIT SPECIALIST. | |
| 11/01/1999 | FRAMING | Denied | IVRS - Inspection 0999* |