Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/08/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. STRAP FLOOR JOISTS AT GARAGE COMMON WALL AND SIDE OF COMMON WALL AT EVERY OTHER JOIST. 2. PROVIDE CALCULATIONS FOR TRUSS #T3. 3. PROTECT CONDENSATION LINES. 4. PROTECT ELECTRICAL. 5. PROVIDE CLEARANCE FOR MECHANICAL FLUES. 6. PROVIDE SHEAR TRANSFERS FOR FLOOR JOISTS AND SECOND FLOOR. |
| 02/08/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 01/05/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - NEED CITY APPROVED TRUSS CALCS, PROVIDE POST TO BEAM CONNECTIONS @ STAIRWALL, PROTECT ELECTRICAL WIRES WITH BANG PLATES, PROVIDE PLYWOOD FOR ACCESS TO FURNACE, PROVIDE CLIPS @ BEARING POINTS UPSTAIRS. |
| 01/05/2000 |
FRAMING |
|
Denied |
DENIED |
| 12/21/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - STOPPED INSPECTION. SUPPORT ABS AT 90 DEGREE SHEARWALLS KNOCKED OUT AT GARAGE. PROVIDE CONDENSATION LINE WITH POSITIVE FLOOR. SHEARWALLS CALL FOR ANCHOR BOLTS AT 24 O.C. HTT 22S LOOSE ANCHOR BOLTS. PROVIDE GROUND TO EXHAUST FANS. FLOOR TRUSSES MISSING H25S. BEAM AT NORTH SIDE OF GARAGE NEEDS CONNECTING ANCHOR BOLTS. TWO MINIMUM SOLE PLATE 12 MIN. FROM END. SUPERINTENDENT WILL WALK YOUR HOUSE BEFORE CALLING FOR INSPECTIONS. |
| 12/21/1999 |
FRAMING |
|
Denied |
DENIED |
| 12/20/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. MISSING H2.5 CLIPS ON TRUSSES. 2. NEED STRAPS AT 2ND FLOOR BATHROOM WALL WEST SIDE WHERE PLUMBING VENT RUNS THRU ROOF. 3. STRAPS NOT NAILED DOWN 2ND FLOOR AT HEX WINDOW. |
| 12/20/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 12/07/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - INSPECTION CANCELLED BY SUPER. |
| 12/07/1999 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |