Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T99CM03611

Parcel: 136221900


Addresses:

7791 E RHIANNON DR


Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T99CM03611

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Correction Required

Date Description Inspector Results Comments
09/07/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. MISSING NAILING AT REAR SHEAR, TOP PALTE 2. GIRDER TRUSS CRACKED, MISSING GUSSET PLATE. 3. FILL ALL NAIL HOLES IN THE HANGERS WILL CHECK AT INTERMEDIATES.