Permit: T99CM03529

Parcel: 131090810


Addresses:

5724 E 24TH ST

Inspection Status: Correction Required

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
10/22/1999 PLUMBING - GAS PRESSURE TEST Correction Required ADDTL COMMS - 1. EXTERIOR GAS LINE APPROX 6 1/2 OK
10/21/1999 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*
10/19/1999 PLUMBING - GAS PRESSURE TEST Correction Required ADDTL COMMS - 1. UNIONS NOT APPROVED FOR BELOW GRADE USE A COMPRESSION FITTING, OR THREADED PIPE WITH A LEFT HAND, RIGHT HAND COUPLING. 2. GAS LINE NOT ALLOWED UNDER HOUSE. 3. ALL IRON FITTINGS NEED TO BE WRAPPED.
10/19/1999 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection 0000*