Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/26/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 06/25/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) WASTE VENTS ON NORTH OF BUILDING HAVE REVERSE FLOW AND TRAPPED-NOT ALLOWED THEY MUST CONTINOUSLY FLOW AND TRAPPED-NOT ALLOWED THEY MUST CONTINOUSLY FLOW UP AND EXHAUST 6" ABOVE ROOF 2) EXTEND GAS SLEEVE TO GRADE AND INSTALL CAP VENT |
| 06/19/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) WASTE VENTS MUST EXHAUST A MINIMUM OF 6" ABOVE ROOF LINE 2) OUTSIDE GFCI OUTLET COVERS NO WEATHER TIGHT (LOOSE) 3) ONE GFCI OUTLET HAS NO POWER 4) GAS LINE CANNOT BE UNDER COVERING UNDER A PORCH 5) OUTSIDE HOSE BIBS REQUIRE ANTI-SIPHON VALVES 6) EXTEND OUTLET IN LAUNDRY TO FLUSH W/WALL |