Permit: T99CM03434

Parcel: 141183090

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/27/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - PARTIAL - FILL GAP BETWEEN ROOF AND GARAGE SHEARWALL.
08/27/1999 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*
08/25/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. SHEAR AT GARAGE FRONT RIGHT NOT NAILED AT BOTTOM PLATE. 2. REPLACE BROKEN STUD GARAGE RIGHT AND RECLIP. 3. BACK SHEAR WALL IS NOT NAILED AROUND MASTER BATH WINDOW. 4. CLIP EACH STUD PER 8/A8. 5. SHIM CAP AT GARAGE SHEAR WALL AT ROOF LINE. 6. CHECK NAILING AT FRONT SHEAR WALL BY WINDOW. 7. STRINGERS MISSING ON TRUSSES A & B PER TRUSS CALCULATIONS.
08/25/1999 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*