Inspection Status: Denied
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/16/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |
| 09/13/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. 3/A8 NOT COMPLIED WITH 2. DOUBLE 2X8 HEADER AT ENTRY NOT COMPLIED WITH. 3. SAFETY BRACE REQUIRES 2-16D NAILS EACH END 4. NAIL RSP4 AT CORNERS, FILL ALL HOLES. 5. PROVIDE APPROVED DETAIL FOR NAILING CHANELS OF INTERIOR WALLS INTERSECTING EXTERIOR WALLS WIHT DRY WALL SHEAR 6. STRAP CORNERS WITH NON OVER LAPPING DOUBLE TOP PLATE. 7. REMOVE TEMPORARY BRACE AT EAST WALL. 8. O.S.B ROOF PANELS LOOSE. RENAIL ALL SHINERS AND LOSSE PANELS PER NAIL SCHEDULE 9. 1/A8 NOT COMPLIED WITH. |
| 09/13/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |