Permit: T99CM03386

Parcel: 12307125A


Addresses:

1221 N OLSEN AV

Inspection Status: Approved

Inspection History: STUCCO MESH

Date Description Inspector Results Comments
04/25/2001 STUCCO MESH Approved IVRS - Inspection 0000*
11/17/2000 STUCCO MESH Partial Approval IVRS - Inspection 0000*/THERE IS PRESENTLY 3/8" BETWEEN WEEP SCREED EDGE AND LATH BACK FOAM. CHECK FOR A TOTAL OF 7/8" STUCCO WHEN INSTALLED.
11/14/2000 STUCCO MESH Denied IVRS - Inspection 0999*/WESTERN ONE COTE STUCCO SYSTEM DOES NOT QUALIFY FOR ONE HOR FIRE RATING YOU MUST COMPLY WITH U.B.C. TABLE 7-B ITEM FOAM NOT ALLOWED. AND SECTION 2508 EACH COTE MUST BE INSPECTED TO VARIFY THICKNESS.