Inspection History Details
Inspection Status: Correction Required
Inspection History: FRAMING
Permit Number - T99CM03263
Inspection Description - FRAMING
Inspection Status - Correction Required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/10/2000 | FRAMING | Correction Required | ADDTL COMMS - 1. NEED TWO GRD. RODS, PLEASE EXPOSE THEM. | |
| 11/16/1999 | FRAMING | Correction Required | ADDTL COMMS - 1. GAS LINE EMBEDED IN SLAB UNDER BUILDING NOT TOO BE THERE 2. PVC H2O LINES IN SIDE THE BLDG NOT CODE 3. FROM LAST INSPECTION ID THE 1 METAL PIPE UNDER THE BLDG 4.SOMETIME BETWEEN DRYWALL AND NEXT INSPECTION I WILL RESEARCH WHETHER YOU NEED A LANDING INSIDE FOR DOOR SWING. 5. FROM LAST INSP GAS TO KIT NOT ON PLAN GUEST HOUSE KITCHEN | |
| 11/16/1999 | FRAMING | Not ready for Inspection | NOT READY FOR INSPECTION | |
| 10/27/1999 | FRAMING | Correction Required | ADDTL COMMS - 1. USE CORRECT TYPE EXHAUST FAN DUCTING-NO PLASTIC. 2. BLOCK ALL MECH. DUCTS 3 SIDES. 3. NO FRAMING PLAN. 4. WHAT IS 1 METAL PIPE BELOW SLAB, UNDER BLDG. 5. NOTHING ON PLAN SHOWING GAS LINE, AND ELECT. FOR RANGE. 6. NEED A DRYER VENT. 7. INSULATE ALL DUCT WORK. 8. NEED COMB AND RELIEF AIR FOR H2o HEATER. 9. NEED DI-ELECTRIC UNION GALV. TO COPPER PIPING. 10. GAS LINE PRESS TEST AND SOURCE? | |
| 10/27/1999 | FRAMING | Not ready for Inspection | NOT READY FOR INSPECTION |