Permit: T99CM03263

Parcel: 135083110


Addresses:

7437 E 29TH ST #02


Inspection Status: Correction Required

Inspection History: FRAMING

Permit Number - T99CM03263

Inspection Description - FRAMING

Inspection Status - Correction Required

Date Description Inspector Results Comments
01/10/2000 FRAMING Correction Required ADDTL COMMS - 1. NEED TWO GRD. RODS, PLEASE EXPOSE THEM.
11/16/1999 FRAMING Correction Required ADDTL COMMS - 1. GAS LINE EMBEDED IN SLAB UNDER BUILDING NOT TOO BE THERE 2. PVC H2O LINES IN SIDE THE BLDG NOT CODE 3. FROM LAST INSPECTION ID THE 1 METAL PIPE UNDER THE BLDG 4.SOMETIME BETWEEN DRYWALL AND NEXT INSPECTION I WILL RESEARCH WHETHER YOU NEED A LANDING INSIDE FOR DOOR SWING. 5. FROM LAST INSP GAS TO KIT NOT ON PLAN GUEST HOUSE KITCHEN
11/16/1999 FRAMING Not ready for Inspection NOT READY FOR INSPECTION
10/27/1999 FRAMING Correction Required ADDTL COMMS - 1. USE CORRECT TYPE EXHAUST FAN DUCTING-NO PLASTIC. 2. BLOCK ALL MECH. DUCTS 3 SIDES. 3. NO FRAMING PLAN. 4. WHAT IS 1 METAL PIPE BELOW SLAB, UNDER BLDG. 5. NOTHING ON PLAN SHOWING GAS LINE, AND ELECT. FOR RANGE. 6. NEED A DRYER VENT. 7. INSULATE ALL DUCT WORK. 8. NEED COMB AND RELIEF AIR FOR H2o HEATER. 9. NEED DI-ELECTRIC UNION GALV. TO COPPER PIPING. 10. GAS LINE PRESS TEST AND SOURCE?
10/27/1999 FRAMING Not ready for Inspection NOT READY FOR INSPECTION