Inspection Status: Correction Required

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
09/07/1999 ELECTRIC - FINAL Correction Required ADDTL COMMS - 1. SMOKE DETECTOR REQUIRED TO BE ON SEPERATE CIRCUIT PER PLAN
09/07/1999 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*
09/02/1999 ELECTRIC - FINAL Correction Required ADDTL COMMS - 4. EXCESS OF 24 TO OUTLET AT COUNTER RT OF KITCHEN SINK. 5. ALL ELECTRIC OUTLETS WITHIN 5 FEET OF SINKS MUST BE GFCI. 6. ISLAND OUTLET CANNOT BE UNDER 6 OVER HANG 7. DISPOSAL OUTLET HOT ALWAYS. 8. WIRES KINKED IN SERVICE PANEL. 9. HOUSE NOT WIRED PER PLAN MISSING CIRCUITS FOR, 7 REF, 11 SMOKE DETECTOR 20 FAU, REVISE PLAN OR PANEL.
09/02/1999 ELECTRIC - FINAL Denied DENIED
08/26/1999 ELECTRIC - FINAL Correction Required ADDTL COMMS - 1. NO POWER TO HOUSE CAN NOT CHECK 6 FLIS 2. SEAL AROUND FLU PIPE THRU CIELING IN GARAGE 3. COMPLETE LABELING PANEL 4. GARAGE DOOR DOES NOT SELF CLOSE.
08/26/1999 ELECTRIC - FINAL Denied IVRS - Inspection 0999*