Inspection Status: Correction Required
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/07/1999 |
ELECTRIC - FINAL |
|
Correction Required |
ADDTL COMMS - 1. SMOKE DETECTOR REQUIRED TO BE ON SEPERATE CIRCUIT PER PLAN |
| 09/07/1999 |
ELECTRIC - FINAL |
|
Partial Approval |
IVRS - Inspection 0000* |
| 09/02/1999 |
ELECTRIC - FINAL |
|
Correction Required |
ADDTL COMMS - 4. EXCESS OF 24 TO OUTLET AT COUNTER RT OF KITCHEN SINK. 5. ALL ELECTRIC OUTLETS WITHIN 5 FEET OF SINKS MUST BE GFCI. 6. ISLAND OUTLET CANNOT BE UNDER 6 OVER HANG 7. DISPOSAL OUTLET HOT ALWAYS. 8. WIRES KINKED IN SERVICE PANEL. 9. HOUSE NOT WIRED PER PLAN MISSING CIRCUITS FOR, 7 REF, 11 SMOKE DETECTOR 20 FAU, REVISE PLAN OR PANEL. |
| 09/02/1999 |
ELECTRIC - FINAL |
|
Denied |
DENIED |
| 08/26/1999 |
ELECTRIC - FINAL |
|
Correction Required |
ADDTL COMMS - 1. NO POWER TO HOUSE CAN NOT CHECK 6 FLIS 2. SEAL AROUND FLU PIPE THRU CIELING IN GARAGE 3. COMPLETE LABELING PANEL 4. GARAGE DOOR DOES NOT SELF CLOSE. |
| 08/26/1999 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999* |