Inspection Status: Correction Required
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 08/20/1999 |
PLUMBING - ROUGH, SOIL |
|
Correction Required |
ADDTL COMMS - 1. SOIL WATER TEST OK 2. BLDG DRAIN CONNECTION TO EXSISTING BLDG DRAIN OK 3. OK TO BACKFILL TRENCH 4. NOTE: WILL REQUIRE A REVISED PLAN CHANGE AND APPROVAL OF WASTE LINE BEFORE FINAL |
| 08/09/1999 |
PLUMBING - ROUGH, SOIL |
|
Correction Required |
ADDTL COMMS - 1. FLAT VENT @ WATER CLOSET MUST BE @ 45 DEGREES. 2. CAN NOT USE FERNCO COUPLING WHERE 3 ABS CONNECTS TO EXISISTING BLDG DRAIN. SPECIALTY COUPLING IS THE APPROVED COUPLING FOR THIS APPLICATION. 3. MUST PAY REINSPECTION FEE BEFORE NEXT INSPECTION. |
| 08/09/1999 |
PLUMBING - ROUGH, SOIL |
|
Denied |
DENIED |
| 08/04/1999 |
PLUMBING - ROUGH, SOIL |
|
Correction Required |
ADDTL COMMS - 1. NO WATER TEST ON SOIL 2. FERNCO COUPLING WHERE 3 BLDG DRAIN CONNECTS TO EXISTING CAST IRON NOT A APPROVED COUPLING WITHIN BLDG 3. FLAT VENT FOR WATER CLOSET NOT @ 45 DEGREE OF SPRING LEVEL |
| 08/04/1999 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0000* |
| 07/15/1999 |
PLUMBING - ROUGH, SOIL |
|
Correction Required |
ADDTL COMMS - 1. ROUGH SOIL NOT COMPLETED 2. CA N NOT HAVE FERMCO COUPLING UNDER SLAB 3. NEED 3 LONG SWEEP ON BLDG DRAIN 4. CAN NOT FLAT VENT WITH 3X2 LOW HEEL 1/4 BEND @ WATER CLOSET 5.CAN NOT HAVE SOULDERED JOINTS UNDER SLAB 6. WATER HTR NOT TO CODE A-P&T DRAIN MUST GO TO DAYLIGHT B- FLU PIPE MUST BE DOUBLE WALL WITH APPROVED FLU CAP 7. SOIL ROUGH IN MUST HAVE WATER TEST. |
| 07/15/1999 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0000* |