Permit: T99CM03062

Parcel: 127022690


Addresses:

5324 E 1ST ST

Inspection Status: Correction Required

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
08/20/1999 PLUMBING - ROUGH, SOIL Correction Required ADDTL COMMS - 1. SOIL WATER TEST OK 2. BLDG DRAIN CONNECTION TO EXSISTING BLDG DRAIN OK 3. OK TO BACKFILL TRENCH 4. NOTE: WILL REQUIRE A REVISED PLAN CHANGE AND APPROVAL OF WASTE LINE BEFORE FINAL
08/09/1999 PLUMBING - ROUGH, SOIL Correction Required ADDTL COMMS - 1. FLAT VENT @ WATER CLOSET MUST BE @ 45 DEGREES. 2. CAN NOT USE FERNCO COUPLING WHERE 3 ABS CONNECTS TO EXISISTING BLDG DRAIN. SPECIALTY COUPLING IS THE APPROVED COUPLING FOR THIS APPLICATION. 3. MUST PAY REINSPECTION FEE BEFORE NEXT INSPECTION.
08/09/1999 PLUMBING - ROUGH, SOIL Denied DENIED
08/04/1999 PLUMBING - ROUGH, SOIL Correction Required ADDTL COMMS - 1. NO WATER TEST ON SOIL 2. FERNCO COUPLING WHERE 3 BLDG DRAIN CONNECTS TO EXISTING CAST IRON NOT A APPROVED COUPLING WITHIN BLDG 3. FLAT VENT FOR WATER CLOSET NOT @ 45 DEGREE OF SPRING LEVEL
08/04/1999 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0000*
07/15/1999 PLUMBING - ROUGH, SOIL Correction Required ADDTL COMMS - 1. ROUGH SOIL NOT COMPLETED 2. CA N NOT HAVE FERMCO COUPLING UNDER SLAB 3. NEED 3 LONG SWEEP ON BLDG DRAIN 4. CAN NOT FLAT VENT WITH 3X2 LOW HEEL 1/4 BEND @ WATER CLOSET 5.CAN NOT HAVE SOULDERED JOINTS UNDER SLAB 6. WATER HTR NOT TO CODE A-P&T DRAIN MUST GO TO DAYLIGHT B- FLU PIPE MUST BE DOUBLE WALL WITH APPROVED FLU CAP 7. SOIL ROUGH IN MUST HAVE WATER TEST.
07/15/1999 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0000*