Inspection History Details
Inspection Status: Correction Required
Inspection History: FRAMING
Permit Number - T99CM03033
Inspection Description - FRAMING
Inspection Status - Correction Required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/04/2000 | FRAMING | Correction Required | ADDTL COMMS - 1. FROM LAST INSP. DBL. STUDS REQD AT X BRACING AT GARAGE TO HOUSE WALL, WALL BRACING. 2. GARAGE ROOF TO MAIN HOUSE DOES NOT NEED TO BE CONNECTED? | |
| 01/04/2000 | FRAMING | Not ready for Inspection | NOT READY FOR INSPECTION | |
| 12/16/1999 | FRAMING | Correction Required | ADDTL COMMS - NEED COVER PLATE & ROMEX CONNECTOR AT F/PLACE ROMEX ENTRY TO UNIT. KITCHEN COUNTER TOP OUTLETS NEED TO BE SECURED. SOME ARE VERY LOOSE. FROM LAST INSP GARAGE ROOF TIE INTO MAIN HOUSE (SCREW T/CHORD OF TRUSS OF OSB). NEED BUSHING WATER SERVICE AT GARAGE TOP PLATE. 5 RU OUTLET FURNACE? BUSHING TOP PLATE HOSE BIB FRONT BEDROOM. SCREW BRACES. NEED 2 STUDS AT HDS. SEE PLAN | |
| 12/16/1999 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* |