Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/19/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. FINISH SCREWING O.S.B. TO INTERIOR/ABOVE AND BELOW GARAGE TO HOUSE GABLE. 2. ATTACH GARAGE ROOF TO MAIN HOUSE WITH SCREWS. 3. NO PAPERWORK WITH PER FOR X BRACE BOLTS INSPECTED. 4. MISSING BRACING AT GARAGE TO HOUSE WALL AND EACH SIDE OF BAY WINDOW. 5. BRACING PLAN LABEL IS MONTEREY AND COLUMN PLOT IS LABELED KYLIE?
11/19/1999 EXT METAL CLIPS/EXT SHEATHING Partial Approval PARTIAL APPROVAL