Inspection History Details
Inspection Status: Correction Required
Inspection History: FRAMING
Permit Number - T99CM02929
Inspection Description - FRAMING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/17/1999 | FRAMING | Correction Required | ADDTL COMMS - THIS INSPECTION IS APPROVED SUBJECT TO THE APPROVAL OF THE TRUSS TO WALL CONNECTION DETAIL BY CITY OF TUCSON PLANS EXAMINER. THIS DETAIL CAN BE WALKED THROUGH. | |
08/13/1999 | FRAMING | Correction Required | ADDTL COMMS - FURNISH AN APPROVED DETAIL AS REQUESTED OF ATTACHMENT TO WALL BELOW. | |
08/13/1999 | FRAMING | Denied | IVRS - Inspection 0999* | |
08/11/1999 | FRAMING | Correction Required | ADDTL COMMS - DENIED - THE CRIPPLE STUDS AT CENTER WALL REQUIRE CLARIFICATION BY THE PLANS DESIGNER. HOW WILL THE DEFLECTION OF THE TRUSSES BE ADDRESSED AT THE SUBJECT WALL? SUBMIT A REVISED DRAWING (DETAIL) TO DEVELOPMENT SERVICES PLANS REVIEWER FOR APPROVAL. (CITY). | |
08/11/1999 | FRAMING | Denied | IVRS - Inspection 0999* | |
08/10/1999 | FRAMING | Correction Required | ADDTL COMMS - DENIED - CORRECTIONS NEEDED: 1. FRAME FAU AND WATER HEATER. CUBICLES 16 O.C. ADD BLOCKING, ADD FIRESTOP BELOW PLATFORM. 2. ADD BLOCKING TO SUPPLY AIR REGISTERS. ANY SIZE ON 3 SIDES. 3. ADD RAT RUN BRACE TO SCISSOR TRUSS. RUN BETWEEN GARAGE AND REAR BEDROOM. 4. ADD CUTT NAILS TO INTERIOR PARTITIONS WHERE MARKED OR NEEDED. 5. GROUT TUB BOXES. 6. PROVIDE ENGINEERS DETAIL FOR THE CRIPPLE STUDS ADDED AT THE TOP OF CENTER WALL. HOW WILL DEFLECTION OF TRUSSES BE ACCOMPLISHED. THIS IS NOT A MIS-SPAN BEARING WALL. 7. LAVATORY DRAIN LINE IS FARTHER THAN 5 FROM ITS VENT. REVENT AND SHORTEN DISTANCE. | |
08/10/1999 | FRAMING | Denied | IVRS - Inspection 0160* |