Permit: T99CM02743

Parcel: 136327560

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
09/17/1999 FRAMING Correction Required ADDTL COMMS - 30 HEADROOM NEEDED AT ATTIC ACCESS.
09/16/1999 FRAMING Denied IVRS - Inspection 0950*
09/15/1999 FRAMING Correction Required ADDTL COMMS - 1. SHEAR WALL #6 MISSING BLKS 2. TRUSS INFORMATION NEEDED FOR FURNACE AREA. 3. HANGER FURNACE PLATFORM 4. BLK DUCT WORK 3 SIDES 5. 2 STRINGERS MISSING ON CO1 TRUSSES AND 1 MISSING ON A01S 6. SEE ITEMS 1,4,5&6 ON PREVIOUS INSPECTION
09/15/1999 FRAMING Denied IVRS - Inspection 0999*
09/07/1999 FRAMING Correction Required ADDTL COMMS - 1. FIRE BLOCK ARCH WAYS. 2. STRAP GLB TO POST 3. REINSTALL BLOCK FOR OSB SHEAR 4. MOVE PEX FROM CAN LIGHTS 12 5. DUCT RESTRICTED AT WEST FAU OVER BEDROOMS. 6. ATTIC ACCESS ABSTRUCTED (DUCT) 7. TIGHTEN HOLD DOWNS. 8. CONSULT TRUSS ENGINEER FOR APPROVAL ON FAU INSTALLATION ON DEAD WOOD. 9. STOPPED INSPECTION
09/07/1999 FRAMING Denied IVRS - Inspection 0999*