Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/27/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - BEFORE NEXT INSPECTIONS GET APPROVAL FOR RED HEADS WHERE ANCHOR BOLTS WERE MISSED. |
| 08/24/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - RECALL. CHECK NAILS AT GABLE END. PLAN CALLS FOR SHEAR WALLS TO BE BLOCKED AT ALL SEAMS. INSTALL BANG PLATES WHERE PLUMBING & ELECTRICAL MAY BE PUNCTURED, WHERE ABS ARE MISSING HAVE PLANS REVISED FOR APPROPRIATE HOLD DOWN. |
| 08/24/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
DENIED |