Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/13/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - STRINGERS MISSING ON TRUSSES. INSTALL BEFORE LOADING ROOF. CHECK AT FINAL FRAME. |
| 08/12/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - VERTICAL METAL TIES AT PORCH BEAMS TO TOP PLATE PAPERWORK ON OVER FRAMING AT BACK VALLEYS COMPLY WITH DETAIL 1/0 AT BACK BEARING WALL, CLARIFY BEAM CONN. TO POSTS AT FRONT PORCH |
| 08/12/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |