Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/19/2000 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 11/29/2000 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/DOUBLE BOWL SINK NOT ALLOWED IN THIS UNIT. IF YOU DESIRE TO MAINTIAN A DOUBLE BOWL SINK YOU MUST HAVE YOUR PLANS REVISED AND APPROVED BY CITY OF TUCSON. |
| 11/02/2000 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1. FIRE PROOF CAULK FIRE PLACE GAS LOG LIGHTER. 2. PROVIDE ONE KOTE STUCCO INSTALLATION CERTIFICATE. 3. PLAN REQUIRES SINGLE BOWL KITCHEN SINK DOUBLE INSTALLED BUILD TO PLAN OR HAVE PLAN REVISED TO AS BUILT. 4. KITCHEN COUNTER LEFT OF SINK REQUIRES GFCI OUTLET WITHIN 24" OF END OF COUNTER. 5. OPEN CABLE TRENCH. 6. ELECTRIC SERVICE 6. ELECTRIC SERVICE REQUIRES NON WATER BOND LABLE 7. 6 EACH MULTI WIRED CIRCUITS IN HOUSE DO NOT COMPLY WITH NEC SECTION 210.4. 8. PROVIDE SUPPORT FOR W/H EXPANSION TANK. NOT BY PLUMBING. 9. PARKING FOR GUEST HOUSE NOT IN. |