Permit: T99CM02573

Parcel: 125073600


Addresses:

2324 E 6TH ST

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
04/07/2000 FRAMING Correction Required ADDTL COMMS - PARTIAL - ALL BUT WINDOW.
04/07/2000 FRAMING Partial Approval IVRS - Inspection 0000*
04/06/2000 FRAMING Correction Required ADDTL COMMS - DENIED - ITEMS 1 & 4 OF 04-05-00 ARE OPEN.
04/06/2000 FRAMING Denied IVRS - Inspection 0999*
04/05/2000 FRAMING Correction Required ADDTL COMMS - DENIED - 1. POST FOR KITCHEN LINTEL IS NOT ADEQUATELY BEARING ON EAST END. AT FLOOR/STEM WALL. 2. B X CABLE IS NOT PROPERLY SPLICED SOUTH OF KITCHEN SINK. 3. GAS AND WATER COPPER REQUIRE ELECTRIC BOND. 4. WINDOW WITHIN 24 OF DOOR MUST BE SAFETY GLAZED. 5. RAFTER/JOIST AT NORTHEAST CORNER OF GREAT ROOM MUST BEAR ON HANGER.
04/05/2000 FRAMING Denied IVRS - Inspection 0999*
03/29/2000 FRAMING Denied IVRS - Inspection 0999*