Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/13/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - APPROVED PER ENGINEERED DETAIL ON PORCH ROOF CONNECTION - TO BE ATTACHED TO FINAL INSPECTION. OSB SHEAR NEEDED BACK WALL N. 1/2. ANCHORS NEEDED INTERIOR BEARING WALL |
| 10/04/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - EXTERIOR BEARING STUD KNOTCHED OVER 25% AT N.W. CORNER. #3 SHEAR MISSING AT FRONT RETURN WALL LSS HANGERS NEED 7 10S PER JOIST. NEED DETAIL FOR SHED ROOF CONNECTION. INTERIOR BEARING CONNECTION NEEDED. NAILING MISSING ON ROOF PANELS AND HIP RIDGES. |
| 10/04/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |