Inspection Status: Denied
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/10/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |
| 06/09/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. CLIP HEADERS TO KING STUDS. 2. CLIP ALL TRUSSES PER PLAN. 3. MIN 1/2 CLEARANCE FROM TRUSSES TO NON BEARING WALLS. 4. ADD GABLE END BRACES PER PLAN. 5. MISSING A35 IS AT FRZ BLOCKING. 6. PAHD HOLD DOWN NOT INSTALLED REAR OF HOUSE. NEED SPECIAL INSPECTION REPORT FOR CORRECTION. |
| 06/09/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |