Inspection Status: Correction Required
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/12/2000 |
ELECTRIC - FINAL |
|
Correction Required |
ADDTL COMMS - 1. BASE BOARD ELECTRIC HEATERS MUST BE ON DEDICATED CIRCUIT NOT PLUGGED INTO A CONVENIENCE OUTLET. 2. NEW BEDROOM AND BATH CONVENIENCE OUTLETS WIRED INCORRECTLY HOT GROUND. |
| 01/12/2000 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999* |
| 12/21/1999 |
ELECTRIC - FINAL |
|
Correction Required |
ADDTL COMMS - 1. OUTSIDE ELECTRIC OUTLET MUST BE DEDICATED OR GFCI. WIRE HOT WRONG. 2. HIP RAFTERS MUST BE CLIPPED W/H.2.5 CLIPS. 3. FILL UN-USED C/B IN SERVICE PANEL. 4. BASE BOARD ELECTRIC HEATERS MUST BE ON DEDICATED CIRCUITS. HARD WM 30. 5. ALL ELECTRIC OUTLETS WIRED INCORRECTLY HOT AND NEUTRAL REVERSED IN BED ROOM AND TWO, BY THE DOOR, IN DINING ROOM |
| 12/21/1999 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999* |