Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
11/18/1999 ELECTRIC - INTERMEDIATE Correction Required ADDTL COMMS - 1)ELEC CIR REQ FOR FUTURE ELEC FAN FOR BATH & EXST RELOCATION NOT ACCOMPLISHED,BASIC WIRING OK 2)SHOWER REQ PRESSURE/THERMAL BALANCE ANTI SCALD VALVE 3)YOU MUST INSTALL AN ACCESS PANEL TO TUB DRAIN- SLIP JOINT FITTING 4)PROVIDE NAIL PROTECTION FOF ALL PLBG WITHIN 1/4 OF STUD SURFACE 5) SUPPORT SHOWER HEAD AT DROP EAR ANGLE 6) INSTALL H-2.5 CLIPS ON HIP RAFTOR 7) NAIL PROTECT WIRES
11/18/1999 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*
11/02/1999 ELECTRIC - INTERMEDIATE Correction Required ADDTL COMMS - 1. THE ELECTRICAL WIRING IS NOT PER CODE. 2. THE CIRCUITS ARE JUMBLED IN LIGHTING BOXES. TOO MANY WIRES 3. ALL CABLES ENTERING STEEL BOXES MUST BE CLAMPED WITH A ROMEX CONNECTOR. 4. ROMEX IS NOT PROPERLY SUPPORTED.
11/02/1999 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*
10/26/1999 ELECTRIC - INTERMEDIATE Correction Required ADDTL COMMS - INCOMPLETE
10/26/1999 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*