Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T99CM02173
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/26/2000 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
10/04/2000 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/1. NO POWER TO BACK PORCH GFCI CIRCUIT. 2. GARARGE OUTLET MUST BE GFCI NEED INSULATION AND STUCCO CERTS ROOF TOP OUTLET MUST BE GFCI. |