Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T99CM02171
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/26/2000 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
10/04/2000 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/1. NO POWER TO BACK PORCH GFCI OUTLET. 2. MASTER BATH GFCI HOT WHEN TRIPPED. 3. NEED INSULATION AND STUCCO INSULATION CERTIFICATES. 4. ROOF TOP OUTLETS MUST BE GFCI. 5. WINDOW WITHIN 5 FEET OF TUB FLOOR IN WET AREA MUST BE SAFETY GLAZED. |