Inspection Status: Correction Required
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 05/05/1999 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Correction Required |
ADDTL COMMS - AFTER HOURS INSPECTION RECEIVED CHECK NO. 1099 FROM WRIGHT CO. IN PAYMENT OF AFTER HOURS INSPECTION. |
| 05/03/1999 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Correction Required |
ADDTL COMMS - 1. ANY REVISIONS MUST BE APPROVED BY THE CITY OF TUCSON AND BE STAMPED BY APPROPRIATE AGENCIES. THE REVISIONS LEFT AT INSPECTION ARE NOT. 2. SECTION B SHOWS 2-#4 HORIZONTALLY IN THE PATIO FOUNDATION. SECTION A SHOW 2#4 VERTICALLY IN THE HOUSE FOUNDATION. 3. THERE ARE ONLY 5 POST FOUNDATIONS PREPARED PLANS CALL FOR 9. SECTION B SHOWS 2-#4 HORIZONTALLY AROUND PERIMITER OF PATIO SLABS AS WELL- NOT THERE. PLEASE HAVE REVISIONS APPROVED AND RECALL. |
| 05/03/1999 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999* |